A Complete Access To 315 kVA Transformer

315 kVA transformer is a distribution transformer. With the 315 kVA transformer, you may reduce emissions and achieve significant energy savings. They are modest, have a small loss, have low noise, and have excellent efficiency.315 kVA transformers regulate electricity by switching between large and small voltage and current-voltage sources.

315 kva transformers
They produce power, but not in the same way as generators, measured in kilowatts. You can calculate the power of transformers by k.V.A, which refers to kilovolt amperes. 

Typically, the transformer only measures the apparent power, which consists of the voltage and the current.

 

This post will teach you everything you need about the 315 kVA transformer. If you're in the market for a 315kVA transformer, use this guide to identify its features and specifications.

 

What Is A 315 kVA Transformer?

In the field of electricity, a 315 KVA transformer is an electrical device with the capacity to handle 250 kilowatts of power.

315 kva transformer
Each winding shows the number of ampere-turns required to generate one volt. Transformers with a 315 kVA rating transform the incoming electricity into the output power that can run the load.

 

The primary and secondary windings of a 315 kVA transformer usually have separate enclosures. The primary winding is the path of the input power. At the same time, the energy is subsequently transformed by the secondary winding and transmitted to the load via the input terminals.

 

In many cases, the V.A. or kVA rating of the transformer is identical to the power required by the load. For instance, a 1kVA transformer is necessary for a 1000-watt (kilowatt) load with a unity power factor. To meet modern demands, the transformer's kVA rating should be a little higher than the load's.

 

Generally, to get the most out of their transformers, businesses need to know how much power each can produce. 

Learn more: The Ultimate Guide To 400kVA Transformer

 

What Are The Types Of 315kVA Transformers?

Smaller transformers with ratings up to 315 kVA are typically single-phase, dry-type, oil-immersed transformers.

315kVA transformers are a low-cost alternative for some networks, especially those with limited populations. Here at DB Transformer, you can choose different types of  315 kVA transformers designed to meet your requirements. 

315 kva transformer types
Dry Type Transformer

315 kVA dry-type transformers do not use liquid to help them disperse heat. They also do not conform to the standards for their temperature categorization. They either rely on natural airflow or a fan to keep the necessary temperatures inside these transformers.

 

Oil Type Transformer

The 315 kVA oil-type transformers are commonly applied in electricity distribution and electrical substations. They use oil as a cooling and insulating medium for their core and coils. Through circulation, oil moves through ducts within and around the coils and core assembly.

315 kva pad mounted transformer
DB Transformer 315kVA oil-filled transformers include pad-mounted transformers, substation-style transformers, and oil-immersed transformers.

 Get it now: 3 Phase Pad Mounted Transformer

 

Single-Phase Transformer

A single-phase transformer is a good option for a 315 kVA transformer for homes and apartments. This is because of its convenience when powering common appliances. 

An electric and magnetic core is a single-phase transformer that handles single-phase power. Just click on this request, and you may seek the best quotation, and we will indeed offer you the best price that matches your budget.

Related Article

Tips for single-phase transformer

 

What Is The Average 315 kVA Transformer Price?

At Daelim Belefic, a 315 KVA transformer's price typically starts at $1880. However, the most expensive you can get is $18,800.

315 kva transformer price
Here are some of the estimated prices:

  • 315 kVA Dry type transformer: $3,680.00 - $6,500.00
  • 315 kVA Pad-mounted transformer: $8,900.00 - $18,800.00
  • 315 kVA Oil-immersed transformer: $1,800.00 - $5,500.00
  • To better serve its customers, DB Transformer provides the following:
  • 24 Months Warranty
  • Local after-sales installation and maintenance services;
  • Remote Video Installation Guide
  • Trade Assurance Protects
  • On-Time Dispatch Guarantee
  • Refund Policy
  • Transformer Drawings in 1-3 weeks
  • Optional Accessories
  • Transformer Test

Generally, DB Transformer is a leading provider of distribution transformers with three phases and oil immersion in China. These transformers are U.L./cUL, and C.S.A. certified. All designs adhere to international standards such as ANSI/IEEE, D.O.E., C.S.A., AS/NZS, GOST, EN 60076, and NEMA. 

 

In addition, Daelim manufacturers test and thoroughly monitor the transformer through the company's quality control system. To get the best quote, you have to click the link provided, and we will give you the best price possible.

You may enjoy: 50 kVA Transformer, Get the Best Price

 

How Much Does A 315 kVA Transformer Weigh?

Generally, a 315 KVA transformer weight is 1660kg. There will be differences according to different transformer types, materials, efficiency values, etc.

The core consists of high-quality, cold-rolled grain-oriented (C.R.G.O.) annealed steel lamination. It has low loss and good grain characteristics. Users should insulate 315 kVA with hot oil to avoid vibration and noise and securely bolt to the frames. 

 

In most cases, insulation is necessary for all core clamping bolts. To ensure accuracy, the no-load current of a transformer with a rated voltage and frequency of 315 kVA must be less than 2% of the full-load current. The no-load current must rise by at most 5% of the full-load current for every 12% above the rated voltage.

Keep reading: Ultimate Guide To IEEE C57 Standard

 

What Is The 315kVA Transformer's Oil Capacity?

The oil capacity of a 315KVA transformer is 380 liters.

At Daelim, all transformers supplied by the company always have the required amount of oil. According to the requirements of the environment, Daelim can offer vegetable oil with UL certification.

Liters of oil advisable for 315 kVA transformer (not including oil absorbed by the core and coil assembly):

  • Voltage rating of 11/0.433 kV = 500
  • Voltage rating of 22/0.433 kV = 550
  • Voltage rating of 33/0.433 kV =580

Keep in mind the conservator in a 315kVA transformer must be able to hold at least 10% of the oil.

For a 315kVA transformer with an oil conservator, as a rule, the conservator will hold 3% of the total oil supply. A transformer's conservator tank is the cylindrical tank atop the main tank. Once it heats, the tanks provide the oil in the transformer with breathing room.

Related Article

What is the difference between mineral oil and vegetable oil?

 

What Are The 315 KVA Transformer Dimensions?

The 315 KVA transformer has the following dimensions: 835 mm (height), 1125 mm (width), and 1545 mm (long).

The 315 kVA tank's height should provide a minimum vertical clearance of 120 mm from the top yoke to the top cover plate. Meanwhile, manufacturers ensure that they use tie rods made of 16-millimeter-wide MS. They apply this to secure the core of a 315 kVA transformer.

 

On the other hand, the high- and low-voltage sides of 315 kVA transformers often require adequate voltage and current-rated outdoor bushings. Transformer bushings are insulating structures allowing live, current-carrying conductors to flow safely into the transformer's grounded tank.

 

Frequently, manufacturers construct these bushings in two pieces. For the outer bushing, porcelain is necessary. At the same time, the internal bushing consists of a hard insulating material like epoxy, which requires an embedded stem.

Try for free: The Basic Guide of 500kVA Transformer

 

What Are The Specifications Of A 315 kVA Transformer?

Nominal system voltages for 315 KVA transformers are 11KV, with a standard voltage ratio of 11000/400V. Different countries have slightly different voltage levels.

In addition, it has specifications of load losses of 2800W and no-load losses of 324W.

 

The 315kVA transformer tank typically has a robust frame, cooling radiators, and a conservatory.

Magnetic circuits of 315 kVA transformers typically have these components:

• Three legs construction

• Step lap stacking

 

Each strip of 315 KVA transformer (0.23, 0.27, or 0.30mm thick) is on both sides and made from grain-oriented silicon steel. In DB Transformer's view, quality involves meeting all client needs while adhering to all applicable international norms. As a result, DB Transformer has stocked its testing facility with these cutting-edge tools and technologies.

You may enjoy: Pad Mounted Transformer

 

How Much Does A 315 kVA Transformer Cost?

The cost of a 315 kVA 3-phase transformer from the manufacturer typically ranges from $1,500 to $8,000.

As mentioned earlier, the 315 KVA transformers sold by DB Transformer are of high quality and cost anywhere from $1880 to $18,800.

 

DB Transformer will provide you with the lowest price, the highest quality service, and all necessary documentation. These are quotations, technical data sheet, reference list, and manufacturing plan. At the same time, DB Transformer also offers a quality control plan, testing plan, and test report.

db transformer
 

When you purchase a 315 KVA transformer from DB Transformer, rest assured that you will have these benefits: 

  • You can see the production progress of the transformer on the official website at any time.
  • High-quality materials
  • New technology and materials 
  • Small no-load and load losses
  • Uniform magnetic circuit
  • Reliable performance and structure
  • Energy saving

 

DB Transformer has completed over 600 international transformer projects for various end users. These include utilities, construction firms, electrical trading firms, distributors, cryptocurrency facilities, and the renewable energy sector.

 

DB Transformer should be your go-to supplier for all things transformer related. This is especially true if your requirements are for 315 kVA, so don't hesitate to contact them today.

Read my article on: Pad Mounted Transformer CSA C227.4 National Standard of Canada

 

What Is The Maximum Load Of A 315kVA Transformer?

The maximum load of the 315kVA transformer shall not exceed 2% of the full load current. 

The current must be no more than double the rated value at no load. But there are always exceptions, and it usually depends on various circumstances.

 

Allowable Temperature Rise

For example, suppose the ambient temperature is below the maximum value at the rated load. In that case, a 315kVA power transformer can safely operate at a higher MVA than its rating would otherwise allow. The temperature will rise above the safe limit during the warmer months if the unit users apply it at full capacity.

 

Lower Frequency

At lower frequencies, core saturation may become noticeable. The core may still reach saturation resulting in excess primary current and some overheating despite the 17% decrease in kVA.Thus, there will be a corresponding decrease in frequency.

 

Increased in Load

If the load on the second panel of the 315 KVA transformer goes up, the current in both the secondary and primary windings goes up. As the resistance of a transformer winding is set, the secondary voltage goes down linearly. 

 

And the secondary current goes up (load increases). Also, when there is more current in the windings of a transformer, you will lose more copper, which wastes energy as heat.

Overall, overloading the transformer past its design limits could cause the temperature to rise above what is safe.

You may enjoy: Solar Transformer - Your ultimate guide

 

How Many Amps Can A 315 kVA Transformer Handle?

A 315 kVA transformer can handle 120 volts at 1515.4446 amps.

In order to calculate kVA, you need to know at least two things:

  1. to what extent the load's line voltage is higher than (V)
  2. a phase current at full load that (I)
  3. In the case of three-phase transformers, kVA = (V * I * 1.732) / 1000

 

315 (kVA) to amp-hours (A/H) conversion. Multiply 315 kVa by 1000, then divide the result by the voltage to get the current in amps.

 

Therefore,  315kVA equals 1515.54446 A amps at 120 volts, three-phase.

 

Generally, you can calculate the kVA rating by multiplying the winding voltage by the current through the winding at full power.The number of turns in a winding determines its maximum allowable voltage. If there is a voltage drop, the kVA rating will decrease accordingly.

 

What Are The 800 kVA Transformer Dimensions?

800 kva transformerThe 800 kVA transformer has the following dimensions: 1780 mm (height), 2160 mm (width), and 2513 mm (long).


Other specification includes the following:

  • Input: 22,000/4,000 Volts
  • Phasing: 3 Phase
  • Roughly 5% Impedance
  • Weighing in at 2650kg
  • The oil capacity of 645L

An 800 kVA transformer's winding material provides adequate permeability, and no bubbles form. You can also ensure that manufacturers keep it at a minimum partial discharge. In addition, the precise mating of the HV and LV windings guarantees solid structural integrity. It also offers resistance to short circuits and vibration.

 

With DB Transformer products, the service life of the transformer is 30 years. In fact, the winding surface will not crack if the user operates the transformer under normal service conditions.

Reading on The Ultimate FAQs Guide To Oil Type Transformer

 

Where Can You Find 800 kVA And 315 kVA Transformers For Sale?

If you're searching for an 800 and 315 kVA transformer for sale, you can purchase it from DB Transformer

In addition to these products, several transformer devices are also available.

  • Substation Transformers
  • Pad Mounted Transformers
  • Single Phase Transformers
  • HV Power Transformers

Get it now: The Ultimate FAQs Guide To Types of Substation

DB Transformer guarantees quick turnaround and superior quality. We offer transformer-related services, including customization and support before and after the sale.

So far, we have established four international service hubs in the following countries: Canada, the United States, Australia, and Ecuador. Contact DB Transformer to view local project cases.

Daelim is reliable due to our committed customer service, prompt deliveries, and high standards in the transformer industry. Follow the link to contact us, and we'll discuss how to meet your transformer product needs in the best way possible.


Related Products


Related Article

An Encyclopedia of 200 kVA Transformer

Dealim Electric has designed, produced, and tested all kinds of 200 kVA transformers and exports to U.S. and Canada with the CSA, ANSI/IEEE standards. 200 kVA transformers are the only rated capacity manufactured by Daelim, we can also provide other rated capacity transformers.

Everything You Need To Know With 250 kVA Transformer

Daelim is UL/cUL transformer manufacturer who has been product with ANSI/IEEE,CSA, AS/NZS, GOST, EN standards.The 250 kVA Transformer produced by Daelim can fully meet the DOE efficiency value.Daelim’s 250kVA three -phase transformers and single -phase transformers have been exported to the United States, Canada, Australia, Guyana, Mexico, Panama and other countries.

The Ultimate Guide To 400kVA Transformer

Daelim is a transformer supplier with UL/cUL listed. Daelim offers 400kva oil-immersed transformers and dry-type transformers. Daelim already exported many power distribution transformers and dry transformers around the world and received customers' recognition of product quality.