100 kVA Single Phase Pad Mounted Transformer


  • Primary Voltage Ratings: 34.5-19.92/13.8-7.957/13.2-7.62/12.47-7.2, 27.6/16 ,14.4-7.2,14.4, 7.2, 24.94, 34.5 or others
  • Secondary Voltage Ratings: 120-240/240-480/347/600 or others
  • H.V. TAP RANGE: ±2×2.5% or others
  • CONNECTION TYPE: Delta/Wye
  • TYPE: Dead front/Live front
  • BIL: 30-150
  • Standards: CSA, IEEE, DOE, NEMA
  • Application: Ultility, Building, Residential
  • Power Rating: 100 kVA

Daelim 100 kVA pad mounted transformer meets/exceeds DOE 2016 efficiency ratings with UL/cUL listed. The Daelim Transformer team possesses extensive experience in transformer projects within the North American market. Their service offerings are highly adaptable to suit your specific 100 kVA Transformer requirements. By simply sharing your project specifications with pinruidan@daelim-electric.com, you can expect to receive a meticulously tailored transformer solution, a comprehensive quotation, and even an outline drawing of the transformer.


Quote Now
100 kVA Transformer Specifications
Phase Single phase Std.  IEEE Std
Power rating 100 kVA Fluid Vegetable oil
Mounting Pad Mounted Frequency 60Hz
HV Voltage 12470GrdY/7200 Tap changer 5-position
LV Voltage 240/120 Fluid Capacity 82 GAL
HV BIL 95 kV Total weight 1650 LBS
LV BIL 30 kV HV Bshg. Bushing well & insert
Polarity Additive LV Bshg Stud
Loadbreak switch Four-position Impedance 2.50%
Winding Material Aluminum Paint Color Munsell Green
Efficiency 99.25% Fuses Bayonet & ELSP fuse

Contact Daelim Transformer for special requirements

100 kVA Transformer Accessories
Name Qty Name Qty
Bolt for lifting 4 Pressure relief valve 1
Hinged door 1 ELSP fuse 1
Parking stand bracket 1 Bayonet fuse 1
Flip top cover 1 Drip tray 1
LV bushing 3 Pentahead bolt arrangement 1
Equipotential device 1 Oil level gauge 1
Fill plug 1 Insert with dust cap 2
Drain valve 1 Oil level gauge 1
Ground strap copper 1 Clamp 2
HV bushing well 2 Name plate 1
Grounding terminal  2 Four positon LB switch 1

100 kVA Single Phase Pad Mounted Transformer

7.2 kVA 100 kVA Transformer

The ZGDL-H-100/7.2/0.24(0.12) is a model of 100 kVA single-phase pad-mounted transformer, designed and manufactured by Daelim Transformer. This transformer order hails from a construction company in Alabama, USA, comprising a total of 30 units, all purpose-built for residential projects. These 100 kVA transformers have been painstakingly designed to adhere strictly to IEEE Std C57.12.38 standards, surpassing DOE efficiency values, and displaying a UL-listed nameplate. Notably, they employ an environmentally friendly and safe insulating liquid with an ignition point exceeding 300°C, elevating the overall safety profile of the transformer.

Contact Daelim Transformer

100 kVA Transformer Features

Operating at the standard 60 Hz frequency, these 100 kVA single-phase pad-mounted transformers exhibit exceptional performance. With a primary voltage rating of 12.47GrdY/7.2 kV and a secondary voltage of 240/120V, they achieve an impressive peak efficiency of 99.25%. What distinguishes them is their meticulous design, featuring a four-position load-break switch and a five-position tap changer.

The 100 kVA transformer boasts a sealed tank structure, perfectly aligned with IEEE Std C57.12.00 specifications. This design allows it to operate continuously within a temperature range extending from -5°C to +105°C. The tank's robustness adheres to IEEE Std C57.12.28 standards, ensuring it can withstand 50 kPa (7 psig) gauge pressure without incurring permanent deformation and 103 kPa (15 psig) gauge pressure without compromising cabinet safety.

Send Inquiry Now
100 kVA Transformer Features
100 kVA Transformer Structure

100 kVA Transformer Structure

This 100 kVA transformer adheres to a compartmental-type structure in line with IEEE Std C57.12.28 or IEEE Std C57.12.29 standards. It consists of a tank housing high-voltage and low-voltage cable terminating compartments, thoughtfully positioned side by side along one face of the transformer tank. In this configuration, the high-voltage compartment, fitted with two internally connected high-voltage bushing wells and inserts, a 4-position loadbreak switch, a 5-position tap changer switch, and a bayonet fuse, is situated alongside the low-voltage compartment featuring three stud L.V bushings and an oil level gauge.

Learn More 1PH Pad Mount Transformer

100 kVA Transformer Testing

Every 100 kVA transformer unit from Daelim Transformer undergoes a comprehensive battery of stringent factory tests before it leaves the facility. These tests include dielectric tests and chopped wave tests, conducted in strict adherence to IEEE Std C57.12.38. Additionally, a range of other tests, as specified in IEEE Std C57.12.00 and IEEE Std C57.12.90, are meticulously carried out. Only when these tests meet the stringent IEEE standards are the transformers granted approval for shipment.

To ensure the highest quality and compliance, you have the option to involve a third-party testing agency (such as SGS, UL, CSA, etc.) to oversee Daelim Transformer's testing procedures. Alternatively, you can monitor the entire testing process in real-time through cloud video streaming. Once the transformer testing is completed, Daelim Transformer provides a professionally crafted report document, promptly sending it to you for review and confirmation, adding an extra layer of assurance.

Contact Daelim Transformer
100 kVA Transformer Testing
14.4 kV/7.2 kV 100 kVA Transformer

14.4 kV/7.2 kV 100 kVA Transformer

The ZGDL-H-100/14.4(7.2)/0.24(0.12) stands as a dual high voltage 100 kVA pad-mounted single-phase transformer. This specific transformer order, comprising 8 units, was commissioned from Daelim Transformer by a transformer distributor based in Quebec, Canada. The transformer stands in full compliance with CSA C227.3 and CAN/CSA-C802.1 standards. Its high voltage side operates at 24940GrdY/14400V × 12470GrdY/7200V. A noteworthy feature is the dual voltage switch on the high voltage side, granting the versatility to alternate between 14.4kV and 7.2kV. On the low voltage side, it delivers 240/120V. The transformer is further reinforced with a robust double-fuse protection system, encompassing both bayonet and current-limiting fuses. The high voltage side is additionally outfitted with a 4-position loadbreak switch and a 5-position tap changer switch. It adopts a fully insulated split bushing, bushing well, and insert, all equipped with dust caps. The low voltage side features 3 stud bushings, each with 7 holes.

Get Price

100 kVA Transformer customization

The Daelim Transformer team possesses extensive experience in transformer projects within the North American market. Their service offerings are highly adaptable to suit your specific 100 kVA Transformer requirements. By sending your project specifications to pinruidan@daelim-electric.com, you can expect to receive a meticulously tailored transformer solution, a comprehensive quotation, and even an outline drawing of the transformer. Beyond customization, Daelim Transformer provides comprehensive after-sales service and upholds dedicated installation and maintenance teams operating across the United States and Canada. This ensures a rapid resolution of any issues that may arise following transformer delivery. Moreover, Daelim Transformer maintains a sizable warehouse in the United States, stocked with standard specification transformers to address your urgent requirements promptly.

Contact Daelim Transformer
100 kVA Transformer customization

100 kVA Single Phase Pad Mounted Transformer

Down Loads

Daelim Single Phase Pad Mounted Transformer Catalog

Daelim Single Phase Pad Mounted Transformer Operation And Maintenance Manual

 

Specifications

Model: ZGD-H-100/16/0.24(0.12) HV BIL: 125 kV
Standard manufacturing and testing: CAN/CSA C227.3 & CAN/CSA 802.1                  LV Insulation class: 1.2 kV
Type: loop feed pad mount LV BIL: 30 kV
Installation: Outdoor Audible sound level: 51db
Altitude above sea level/Ambient temperature:1000/50m withstand capability per unit of base current (symmetrical): 35
Altitude≤1500m Duration in cycles: 60
Rated Power: 100 kVA Impedance: 2.5%
HV: 27600/16000V Impedance tolerance: ±7.5%
LV: 120/240 Tank: Mild Steel
Rated Frequency:  60Hz Colors: Munsell Green
Cooling System: KNAN Height::  910mm
Core material: Silicon Steel Core Depth: 1200mm
Refrigerant:: FR3 vegetable oil Width: 965mm
Working-Temperature: -50°C to +40°C Weight
The temperature rise -Top oil: 65°C Oil weight: 230kg
The temperature rise --Winding: 65°C Total weight: 710kg
Hot spot::  80°C  
No load losses at 105% rated voltage: 280W Contact us for special requirements
Load loss at the rated voltage at 85°C: 1010W Tel: +86-10-65003129
Winding material: Copper Phone: +86-13051965423
HV Insulation class: 28 kV

Email: pingruidan@daelim-electric.com

Daelim 100 kVA single phase pad mounted transformer operates safely, reliably, and efficiently and can be installed indoors and outdoors. This type of transformer has a low operating cost, is environmentally friendly, easy to install, and has a low purchase cost, so it is widely used in residential, commercial, and other public places.

Learn more about Pad Mounted Transformer

Transformer Features: The industrial transformer has a rated power of 100 kVA, a primary voltage of 27600/16000V single-phase and a secondary voltage of 120/240V single-phase.The transformer has a primary loop feed and dead front primary connections. Daelim also offers radial feed and dead front primary/live front secondary connections. 

 

The ZGD-H-100/27.6(16)/0.24(0.12) transformer is air-cooled and has no fans. The transformer meets CSA efficiency standards(98.94%). 

 

Insulation Fluid: The ZGD-H-100/27.6(16)/0.24(0.12) transformer uses degradable fr3 vegetable oil. It has the characteristics of fire prevention and high-temperature resistance. Daelim also offers mineral oil and Chinese brand vegetable oil (RAPO).

Learn more about Single Phase Pad Mounted Transformer

Accessories including : 

Core&Coil Assemble: 1
Bayonet fuse: 1
Drip shield Assembly: 1100 kva transformer
Fuse Holder: 1
Backup fuse: 1
Fuse assembly: 1
Pressure relief valve: 1
Oil level gauge: 1
Oil-in flug: 1
Nameplate: 1
HV bushing well and insert: 2
No-load tap changer: 1
Grounding spade terminal: 2
Oil-out plug: 1
Bolt for earth: 1
Copper strip: 1
LV bushing: 3
Bolt for lifting: 4

 

Certificate

Daelim is a professional pad mounted transformer manufacturer. Pad mounted transformer has UL/cUL, CSA, CESI, and other certificates. Can meet the requirements of various international standards, such as ANSI/IEEE, CSA, and DOE efficiency value.

DOE
AS
GOST