50 kVA Single Phase Pad Mounted Transformer


  • Primary Voltage Ratings: 14.4 kV, 7.2 kV, 24.94 kV, 12.47 kV, 14.4/7.2 kV or others
  • Secondary Voltage Ratings: 120-240/240-480/347/600 or others
  • H.V. TAP RANGE: ±2×2.5% or others
  • CONNECTION TYPE: Delta/Wye
  • TYPE: Dead front/Live front
  • BIL: 30-150
  • Standards: IEEE Std C57.12.38/CSA C227.3
  • Application: Ultility, Building, Residential area
  • Power Rating: 50 kVA

Daelim 50 kVA pad mounted transformer meets/exceeds DOE 2016 efficiency ratings with UL/cUL listed. Design and production with ANSI/IEEE, CSA standards.Daelim Transformer's 50 kVA single-phase pad-mounted transformer is extensively employed in the North American market. With their wealth of project experience, Daelim Transformer caters to a diverse clientele, including builders, public utility departments, and transformer distributors and retailers.Daelim Transformer excels in crafting custom solutions tailored to the local environment, climate conditions, and the specific requirements of your project. This commitment ensures the delivery of the highest quality transformer solutions, making them the optimal choice for your project. Daelim Transformer is synonymous with providing the best transformer solutions in the industry.


Quote Now
50 kVA Transformer Specifications
Phase 1 phase Std.  IEEE C57.12
Power rating 50 kVA Fluid Mineral Oil
Mounting Pad Mount Frequency 60Hz
HV Voltage 12470GRDY/7200 Tap changer None
LV Voltage 240/120 Fluid Capacity 55 GAL
HV BIL 95 kV Total weight 1235 LBS
LV BIL 30 kV HV Bshg. Bushing well & insert with dust cap
Polarity Additive LV Bshg Stud with 7 holes
Load break switch None Impedance 2.00%
Winding Material Aluminum Paint Color Munsell Green
Efficiency 99.11% Fuses Bayonet & ELSP fuse

Contact Daelim Transformer for special requirements

50 kVA Transformer Accessories
Name Qty Name Qty
Bolt for lifting 4 Pressure relief valve 1
Hinged door 1 ELSP fuse 1
Parking stand bracket 1 Bayonet fuse 1
LV bushing 3 Pentahead bolt arrangement 1
Equipotential device 1 Oil level gauge 1
Fill plug 1 Insert with dust cap 2
Drain valve 1 Grounding bracket 1
HV bushing well 2 Oil level gauge 1
Grounding terminal  2 Drip tray 1
Name plate 1 Clamp 2

50 kVA Single Phase Pad Mounted Transformer

ZGDL-H-50/7.2/0.24 (0.12)

The ZGDL-H-50/7.2/0.24 (0.12) is a 50 kVA pad-mounted transformer, custom-built by Daelim Transformer for a transformer distributor in Virginia, USA. This batch comprises a total of 40 units, all of which are equipped with UL Listed nameplates and are in compliance with DOE efficiency standards. In terms of design, Daelim Transformer tailored the optimal transformer solution to meet customer needs. This solution omits load switches and tap-changers while prioritizing quality, safety, and reliability. This strategic approach has not only expanded the local market for our customers but has also enhanced their competitive advantage.

Contact Daelim Transformer

50 kVA Transformer Features

These 50 kVA transformers are meticulously designed and manufactured in strict accordance with IEEE Std C57.12.38. They serve as medium-voltage distribution transformers within underground power distribution systems. The primary voltage is rated at 12470GRDY/7200V, with a secondary voltage of 240/120V. Operating at a frequency of 60Hz, these transformers achieve an outstanding efficiency rating of up to 99.11% and boast an impedance value of approximately 2%. Furthermore, the on-load loss value remains under 441W, and the no-load loss value does not exceed 125W. To ensure seamless integration into various environments, the transformers are finished with Munsell Green paint, enabling them to blend harmoniously with their surroundings, including parks, hotels, villas, and residences.

On the high-voltage side, the 50 kVA pad-mounted transformer is equipped with two 15 kV 200A HV bushing wells, each with precision-engineered inserts and protective dust caps. Safety is a paramount consideration, which is why a double fuse protection system, consisting of bayonet and ELSP fuses, is incorporated. This system effectively guards against overcurrents during transformer operation, reducing the risk of damage from short circuits and other faults. The bayonet fuse, known for its plug-in design, simplifies maintenance. To prevent insulating oil from dripping onto other areas of the transformer during maintenance or in the event of a fuse failure, a drip tray is thoughtfully positioned beneath the bayonet fuse installation site.

Get Price
50 kVA Transformer Features
50kVA Transformer Features

50kVA Transformer Features

On the low-voltage side, the 50 kVA pad-mounted transformer is equipped with three LV bushings, enhancing operational flexibility. To facilitate regular monitoring of oil levels within the transformer, an oil level gauge is integrated. Additionally, an anti-theft design is implemented through the use of a pentahead bolt arrangement at the base of the tank, e ensuring that both the 50 kVA transformers and their spare parts remain safeguarded against potential theft.

At Daelim Transformer, they are always committed to delivering power distribution solutions that align seamlessly with your specific needs, underpinned by a steadfast dedication to quality, safety, and reliability.

More Residential Transformer

Dual Voltage 50 kVA Transformer

In October 2022, a transformer retailer in Vancouver, Canada, commissioned Daelim Transformer to supply eight dual-voltage 50 kVA single-phase pad-mounted transformers. The challenge at hand stemmed from the unique dual distribution system lines at the end customer's location, operating at 14.4 kV and 7.2 kV. Consequently, the customer required transformers capable of seamlessly switching between these two voltage levels.

In response, Daelim Transformer developed a bespoke transformer solution, tailored to the specific needs of the end user. A dual high-voltage design was implemented on the high-voltage side of the transformer, featuring a tap on the high-voltage winding connected to a switch. This innovation allows for effortless voltage adjustment across five levels, spanning from 14.4 kV * 7.2 kV, with a variance of ±2 * 2 ½%.

Send Inquiry Now
Dual Voltage 50 kVA Transformer
14.4 & 7.2 kV 50kVA Transformer

14.4 & 7.2 kV 50kVA Transformer

The dual voltage 50 kVA transformers are equipped with a 4-position loadbreak switch, enabling precise control of the AB circuit. In terms of protection, the inclusion of bayonet fuses and current-limiting fuses ensures the transformer's robust defense against potential damage from overcurrents. On the low-pressure side, three low-pressure bushings with seven holes offer enhanced operational versatility. Additionally, an integrated oil level gauge facilitates real-time monitoring.

These 50 kVA transformers are meticulously crafted in strict accordance with CSA C227.3 standards and feature Additive Polarity. The entire batch was delivered in December 2022, following thorough factory testing conducted by Daelim Transformer. The testing regimen encompassed multiple critical assessments, including voltage ratio, winding resistance measurement, no-load loss and no-load current testing, load loss and short circuit testing, applied voltage testing, induced overvoltage withstand testing, insulation resistance testing, leakage testing, and comprehensive external inspections, ensuring high quality and reliability.

Get Price

14.4kV 50 kVA Transformer

The ZGDL-H-50/14.4/0.24(0.12) represents a residential transformer with a high voltage rating of 24.94/14.4kV and a low voltage of 240/120V. This residential transformer order was placed by a utility customer in Montreal, Canada, from Daelim Transformer, encompassing a total of 26 units. What truly sets these transformers apart is their outstanding performance, consistently exceeding the rigorous CSA C227.3 standards. Notably, their transformer efficiency values soar beyond 98.84%, while their impedance values register at approximately 1.9%.

On the high voltage side, these transformers feature an array of essential components, including a four-position loadbreak switch, a bayonet fuse, a 5-position tap changer, and two HV bushings equipped with inserts. On the low voltage side, practical elements are incorporated, such as an oil level gauge and 3 LV bushings, each with 4 holes.

Contact Daelim Transformer
14.4kV 50 kVA Transformer

50 kVA Single Phase Pole Mounted Transformer

Down Loads

Daelim Single Phase Pad Mounted Transformer Catalog

Daelim Single Phase Pad Mounted Transformer Operation And Maintenance Manual

Learn more about Single Phase Pad Mounted Transformer

Specifications

Model: ZGDL-H-50 12.47Y/7.2-240/120 HV BIL: 95 kV
Standard manufacturing and testing: C.57.12.00; C.57.12.28; C57.12.90                 LV Insulation class: 1.2 kV
Type: Loop feed pad mount LV BIL: 30 kV
Installation: Outdoor Audible sound level: 48db
Altitude above sea level/Ambient temperature:1000m/20℃  
Altitude≤1000m  
Rated Power: 50 kVA Impedance: 2%
HV: 12470Y/7200V Impedance tolerance: ±10%
LV: 240/120 Tank: Mild steel 
Rated Frequency:  60Hz Colors: Munsell Green
Cooling System: ONAN Height:: 700mm
Core material: Silicon Steel Core Depth: 1000mm
Refrigerant:: Mineral oil 45# (PCB FREE)   Width: 900mm
Working-Temperature: -45°C to +40°C Weight
The temperature rise -Top oil: 65°C Oil weight: 180kg
The temperature rise --Winding: 65°C Total weight: 560kg
Hot spot::  80°C  
No load losses at 105% rated voltage: 125W Contact us for special requirements
Load loss at the rated voltage at 85°C: 441W Tel: +86-10-65003129
Winding material: Aluminum Phone: +86-13051965423
HV Insulation class:15 kV

Email: pingruidan@daelim-electric.com

Transformer Outline Drawing

50 kva transformer drawing

Daelim 50 kVA single phase pad mounted transformer operates safely, reliably, and efficiently and can be installed indoors and outdoors. This type of transformer has a low operating cost, is environmentally friendly, easy to install, and has a low purchase cost, so it is widely used in residential, commercial, and other public places.

Learn more about Pad Mounted Transformer

Transformer Features: The industrial transformer has a rated power of 50 kVA, a primary voltage of 12470Y/7200V, and a secondary voltage of 240/120V single-phase.It's a loop feed transformer. 

 

The ZGD-H-50/12.47/7.2-240/120 transformer is an ONAN cooling method. The manufacturing and testing standard are IEEE C.57.12.00; IEEE C.57.12.28; IEEE C57.12.90

 

Insulation Fluid: The ZGD-H-50/12.47/7.2-240/120 transformer uses mineral oil 45#. The boiling point and instant ignition point of mineral oil are not lower than 140°, and it is not flammable. It has good insulation and heat dissipation effect, which not only improves the insulation strength but also protects against moisture erosion. Does not produce PCB and other harmful gases. It is harmless to people. If you need vegetable oil, Daelim can provide two brands of FR3 and RAPO for you to choose from.

 

Tap Changer: The ZGD-H-50/12.47/7.2-240/120 transformer has no tap changer.  Daelim can provide 5 position and  7-positon no-load tap changer.

 

Accessories including : 

Core&Coil Assemble: 150kva residential transformers
Bayonet fuse: 1
Drip shield Assembly: 1
Fuse Holder: 1
Backup fuse: 1
Fuse assembly: 1
Pressure relief valve: 1
Oil level gauge: 1
Oil-in flug: 1
Nameplate: 1
HV bushing well and insert: 2
No-load tap changer: 1
Grounding spade terminal: 2
Oil-out plug: 1
Bolt for earth: 1
Copper strip: 1
LV Terminal: 3

Bolt for lifting: 4

 

Certificate

Daelim is a professional pad mounted transformer manufacturer. Pad mounted transformer has UL/cUL, CSA, CESI, and other certificates. Can meet the requirements of various international standards, such as ANSI/IEEE, CSA, and DOE efficiency value.

DOE
AS
GOST