Tier-2 2500 kVA Split Transformer-10500 Delta Primary, 690-690Delta Secondary


  • Primary Voltage Ratings: 10.5kV
  • Secondary Voltage Ratings: 690-690V
  • TYPE: Oil immersed type
  • BIL: 75kV
  • Standards: EN60076
  • Application: Energy Storage
  • Power Rating: 2500kVA (2.5MVA)
  • Certificate: CE

In May 2024, we delivered this 2500 kVA split transformer to our Danish customer for a local energy storage project. This transformer is a three-phase transformer featuring 6 bushings for low-voltage double split. The primary voltage is 10500V Delta, with secondary voltages of 690V Delta and 690V Delta. The transformer winding connection group is Dd0d0, with a frequency of 50 Hz, cooling method of ONAN, and impedance of 5.75%. At its rated capacity of 2.5 MVA, the sound level is 63 dB. The insulating liquid utilized is highly refined non-PCB mineral oil.


Quote Now

Contact Daelim Transformer for special requirements

2500 kVA Transformer Specifications and Data Sheet

Delivered to

Denmark

Year

2024

Model

S-2500kVA-10.5/0.69-0.69kV

Type

Oil Immersed Power Transformer

Standard

EN60076 / IEC60076

Rated Power

2500 kVA (2.5 MVA)

Frequency

50 HZ

Phase

Three

Cooling Type

ONAN

Primary Voltage

10.5 kV

Secondary Voltage

0.69-0.69 kV

Winding Material

Aluminium

Vector Group

Dd0d0

Impedance

5.75%

Tap Changer

NLTC 5-positon

Tap Posn

1-11020V;2-10760V; 3-10500V; 4-10240V; 5-9980V

No Load Losses

1570W

Load Loss at rated voltage

18500W

Color

RAL 7035

Daelim Transformer is a robust transformer manufacturer with multiple production lines, including Pad Mount Transformers, ECO Transformers, Substation Power Transformers, Dry Type Transformers, Pole Mount Transformers, and more. Our primary focus is on providing comprehensive support and services for transformer projects across Europe, America, and Australia.


10.5 kV 2500 kVA TransformerIn May 2024, we delivered this 2500 kVA split transformer to our Danish customer for a local energy storage project. This transformer is a three-phase transformer featuring 6 bushings for low-voltage double split. The primary voltage is 10500V Delta, with secondary voltages of 6900V Delta and 6900V Delta. The transformer winding connection group is Dd0d0, with a frequency of 50 Hz, cooling method of ONAN, and impedance of 5.75%. At its rated capacity of 2.5 MVA, the sound level is 63 dB. The insulating liquid utilized is highly refined non-PCB mineral oil.

 

This transformer embodies advanced design concepts and employs high-quality core, winding materials, and components, ensuring exceptional insulation performance, high efficiency, safety, and reliability. It has successfully met the stringent test requirements for CE certification, holding a CE certificate and fully complying with and exceeding EU standards.

 

Transformer Features

  • Compliant with EN60076 standard, boasting TIER-2 efficiency.
  • Equipped with 6 LV bushings of epoxy resin shovel type, each featuring 6 holes.
  • ATC LV bushing included for enhanced performance.
  • Tank cover outfitted with 4 lifting rings for easy handling.
  • High and low voltage electrostatic shielding, used to eliminate electromagnetic harmonic interference of solar energy.
  • Pressure relief device situated on the top of the tank, capable of rapidly releasing significant pressure within the transformer, automatically reverting to its initial state without manual intervention.
  • Liquid temperature gauge featuring two contacts; when the oil temperature exceeds 90℃, the system triggers an alarm and notification. If the temperature surpasses 105℃, the system automatically disconnects the transformer from the power grid to protect the transformer from damage.
  • Liquid level gauge with two contacts, automatically alerting the remote monitoring system in the event of low or high oil levels.
  • Pressure relief gauge for monitoring internal pressure.
  • Upper fill valve for convenient fluid replenishment.
  • Terminal block for connecting liquid level and temperature gauge contacts wires.
  • No-load tap changer with 5 positions on the HV side, offering flexibility with rated voltages of 10500V and additional options including 10760V, 11020V, 10240V, and 9980V, catering to various operational requirements.
  • Four groups of radiators, strategically positioned on both high and low voltage sides, facilitating efficient heat dissipation.
  • Two ground pads on the LV side for enhanced safety.
  • ATC HV bushing ensuring optimal performance.
  • 3 HV bushings with porcelain construction and 4 holes each.
  • 1 hand hole provided for convenient inspection and routine maintenance of the transformer.

 

Core-Winding-Active-Part-Manufacturing IN Daelim Transformer Shop

2500 kva split transformer manufacturing
 

Transformer Gauges

 

2500 kva- split transformer gauges
 

Transformer LV

 

2500kva transformer low voltage double split
 

 

Daelim Transformer boasts over 20 years of experience, ensuring that each delivered transformer unit undergoes rigorous factory testing and adheres to stringent acceptance standards. Our oil-immersed transformers strictly conform to and surpass the requirements of standards such as EN60076, IEC60076, ANSI/IEEE C57, CSA C88, DOE 2016, AS60076, and others.

daelim transformer eco transformer
 

Scope of Supply

Oil immersed distribution transformers

Rated Power: Up to 5 MVA

HV Rating: Up to 46 kV

DOE