4000 kVA Pad Mounted Transformer


  • Primary Voltage Ratings: 12.47kV Grounded Wye
  • Secondary Voltage Ratings: 34.5kV Delta
  • H.V. TAP RANGE: +/- 2@ 2.5% LV taps
  • TYPE: Dead Front loop feed HV & LV configuration
  • BIL: 90/30kV
  • Standards: IEEE, ANSI, NEMA, NFPA
  • Application: Aux transformers For BESS
  • Power Rating: 4000 kVA
  • Cooling Method: ONAN

The 4000 kVA pad mounted transformer adheres to ANSI, IEEE, and NEMA standards and meets the requirements of Article 450 of the California Electrical Code. It serves as an auxiliary transformer in a Battery Energy Storage System (BESS) in California. Engineered to endure the harmonic voltages and currents generated by inverters, it can also withstand transient overvoltages caused by switching surges and faults. Additionally, it is capable of handling the significant load variations typical in BESS projects.


Quote Now

RATINGS

  • Transformer Type: Three Phase Transformer - Pad-Mounted
  • Number of Windings: Two
  • Frequency: 60 Hertz
  • Capacity (HV & LV): 4000 kVA
  • Cooling Class: ONAN
  • Oil Type: Mineral
  • Temperature Rise: 65°C 

Rated Voltages (Peak Voltage)

  • Primary Voltage Winding (H): 12.47 kV
  • Secondary Voltage Winding (X): 34.5 kV

Winding Connections

  • 12.47 kV Winding (H): Grounded Wye
  • 34.5 kV Winding (X): Delta

BIL Ratings

  • 12.47 kV Voltage (H): 125kV
  • 34.5 kV Voltage (X): 150 kV (200kV BIL winding)

Impedance at Base Capacity Rating: 5.75%

Maximum Sound Level at Maximum Capacity: NEMA TR1

Service Conditions

  • Ambient Temperature Range -40 C to 50 C
  • Altitude above Sea Level <3,300 ft

 

Contact Daelim Transformer for special requirements

  • Tap Changer: 5-position, 2 Above and 2 Below Nominal Voltage 

  • Bay-O-net fuse

  • Current limiting fuse

  • Two-position load break switch

  • Schrader-type valve

  • Oil drain valve

  • Dial type thermometer

  • Pressure relief valve

  • Metal LV-HV barrier

  • Nitrogen filling plug

  • Nameplate

  • HV & LV bushing: dead front bushing

  • Lockable  instrument enclosure

This step-down electrical transformer operates at ±10% voltage. It features electrostatic shielding between the windings to discharge static electricity to the grounded core. The transformer’s surface protective coating is ANSI 61 light gray, providing corrosion resistance.

High and low voltage compartment bushings are of a loop feed design (six bushings), arranged for termination with 600 Amp dead break elbows in accordance with C57.12.34. The hinged compartment door is tamper-resistant, meeting the requirements of ANSI C57.12.28.

Factory Tests
Factory tests are conducted in accordance with ANSI/IEEE C57.12.90, including:

  • Resistance measurements
  • Polarity and phase relation
  • Ratio tests
  • No-load losses and excitation current
  • Load losses and impedance voltage
  • Impulse tests
  • Dissolved gas-in-oil analysis
  • Oil tests

Warranty and Support

Daelim Transformer offers 2-year and optional 5-year warranty services. After receiving your order, Daelim Transformer will provide transformer outline drawings for confirmation within 2-3 weeks. A production plan will be provided within four weeks, with monthly updates on production progress until the transformer is completed. You can access details at any time through our system, including drawing releases, production progress photos, manufacturing completion, final testing, and shipment.